+86-312-6775656

CS2671AX 10kV 20mA AC DC Menahan Instrumen Voltan

Feb 07, 2022

Parameter teknikal

1.Senarai Model

MODEL


CS2670A

ACW: 5kV, 20mA

CS2670A-1

ACW: 5kV, 20mA

CS2670AX

ACW: 5kV, 20mA

CS2670Y

ACW: 5kV, 20mA

CS2671AX

ACW: 10kV, 20mA; DCW: 10kV, 10mA

CS2671BX

ACW: 10kV, 50mA; DCW: 10kV, 20mA

CS2671TX

ACW: 10kV, 100mA

CS2672BX

ACW: 5kV, 100mA

CS2672CX

ACW: 5kV, 100mA DCW: 5kV, 20mA

CS2672DX

ACW: 5kV, 20mA DCW: 5kV, 10mA

CS2673X

ACW: 5kV, 200mA

CS2674AX

ACW: 20kV, 10mA; DCW: 20kV, 10mA

2.Parameter teknikal

(1)CS2670A/CS2670A-1/CS2670AX

MODEL

CS2670A

CS2670A-1

CS2670AX

CS2670Y

 

 

 

 

 

ACW

Voltan output

(0.00~5.00)kV

Kuasa output maksimum

100VA(5.000kV/20mA)

Max. semasa

20mA

Julat semasa

2mA、20mA

Output

bentuk gelombang

gelombang sinus

Bentuk gelombang

Herotan

≤5%(memuatkan atau beban rintangan tulen)

Masa ujian

0.0s ~999s 0=teruskan

Meter Volt

Pelbagai

0.00kV ~ 5.00kV

Ketepatan

±(5%+5 perkataan )

Resolusi

10V

Nilai yang dipaparkan

RMS

 

Ammeter

Pelbagai

JA

0.100mA ~ 20.00mA

Resolusi

JA

2mA:1uA, 20mA:10uA

Ketepatan

±(5%+5 perkataan )

 

Pemasa

Pelbagai

0.0s ~ 999s

Min. resolusi

0.1s

Ketepatan

±(1%+50ms)

Antara muka PLC

Tidak

Tidak

Ya

Tidak

Antaramuka jauh

Ya

(2)CS2671AX/CS2671BX/CS2671TX

MODEL

CS2671AX

CS2671BX

CS2671TX

 

 

 

 

 

 

 

 

AC W

Voltan output

(0.00~10.00)kV

Max.output

Kuasa

100VA

500VA

1000VA

Max. semasa

20mA

50mA

100mA

Julat semasa

2mA、20mA

2mA、20mA、50mA

2mA、20mA、100mA

Output

bentuk gelombang

gelombang sinus

Bentuk gelombang

Herotan

≤5%

Masa ujian

0.0s ~999s 0.0= teruskan

 

 

D CW

Voltan output

(0.00~10.00)kV

Maksimum. output

Kuasa

100VA

500VA

--------------------

Max. semasa

10mA

20mA

--------------------

Julat semasa

2mA、10mA

2mA、20mA

--------------------

Faktor Ripple

≤5%

Masa ujian

0.0s ~999s 0= teruskan

 

 

Meter Volt

Pelbagai

(0.00~10.00)kV

Ketepatan

±(5%+5 perkataan )

Resolusi

10V

Nilai yang dipaparkan

RMS

 

Ammeter

Julat Ukuran

JA

0.100mA ~ 20.00mA

0.100mA ~ 50.00mA

0.100 ~ 100.0mA

DC

0.100mA ~ 10.00mA

0.100mA ~ 20.00mA

--------------------

Resolusi

JA

2mA:1uA,20mA:10uA,50mA(100mA):0.1mA

Ketepatan

±(5%+5 perkataan )

 

Pemasa

Pelbagai

0.0s ~ 999s

Min. resolusi

0.1s

Ketepatan

±(1%+50ms)

Antara muka PLC

Tidak

Tidak

Ya

Antaramuka jauh

Ya

(3)CS2672BX/CS2672CX/CS2672DX

MODEL

CS2672BX

CS2672CX

CS2672DX

 

 

 

 

A C W

Output

Voltan

(0.00~5.00)kV

Maxoutput

Kuasa

500VA

100VA

Max. semasa

100mA

20mA

Julat semasa

2mA、20mA、100mA

2mA、20mA

Output

bentuk gelombang

gelombang sinus

Bentuk gelombang

Herotan

≤5%

Masa ujian

0.0s ~999s 0.0= teruskan

 

 

D C W

Output

Voltan

-----------------------------

(0.00~5.00)kV

(0.00~5.00)kV

Maksimum. output

Kuasa

-----------------------------

100VA

50VA

Max. semasa

-----------------------------

20mA

10mA

Julat semasa

-----------------------------

2mA、20mA

2mA、10mA

Faktor Ripple

-----------------------------

≤5%

Masa ujian

-----------------------------

0.0s ~999s 0= teruskan

 

Meter Volt

Pelbagai

(0.00~50.00)kV

Ketepatan

±(5%+5 perkataan )

Resolusi

10V

Dipaparkan

Nilai

RMS

 

 

Ammeter

Julat Ukuran

JA

0.100mA ~ 100.0mA

0.100mA ~ 100.0mA

0.100mA ~ 20.00mA

DC

----------------------------

0.100mA ~ 20.00mA

0.100mA ~ 10.00mA

Resolusi

2mA:1uA, 20mA:10uA, 50mA:0.1mA

Ketepatan

±(5%+5 perkataan )

 

Pemasa

Pelbagai

0.0s ~ 999s

Min. resolusi

0.1s

Ketepatan

±(1%+50ms)

Antara muka PLC

Tidak

Tidak

Ya

Antaramuka jauh

Ya

(4)CS2673X/CS2674AX

MODEL

CS2673X

CS2674AX

 

 

 

A

C

W

Voltan output

(0.00~5.00)kV

(0.00~20.00)kV

Maksimum. output

Kuasa

500VA

200VA

Max. semasa

200mA

20mA

Julat semasa

2mA、20mA、200mA

2mA、10mA

Output

bentuk gelombang

gelombang sinus

Bentuk gelombang

Herotan

≤5%

Masa ujian

0.0s ~999s 0.0= teruskan

 

 

D C W

Voltan output

--------------------------------

(0.00~20.00)kV

Maksimum. output

Kuasa

--------------------------------

200VA

Max. semasa

--------------------------------

10mA

Julat semasa

--------------------------------

2mA、10mA

Faktor Ripple

≤5%

Masa ujian

0.0s ~999s 0= teruskan

 

Meter Volt

Pelbagai

(0.00~5.00)kV

(0.00~20.00)kV

Ketepatan

±(5%+5 perkataan )

Resolusi

10V

Nilai yang dipaparkan

RMS

 

Ammeter

Julat Ukuran

JA

0.100mA ~ 200.00mA

0.100mA ~ 10.00mA

DC

-----------------------------------

0.100mA ~ 10.00mA

Resolusi

2mA:1uA, 20mA:10uA, 200mA:0.1mA

Ketepatan

±(5%+5 perkataan )

 

Pemasa

Pelbagai

0.0s ~ 999s

Min. resolusi

0.1s

Ketepatan

±(1%+50ms)

Antara muka PLC

Tidak

Tidak

Ya

Antaramuka jauh

Ya


Hantar pertanyaan