Parameter teknikal
1.Senarai Model
MODEL | |
CS2670A | ACW: 5kV, 20mA |
CS2670A-1 | ACW: 5kV, 20mA |
CS2670AX | ACW: 5kV, 20mA |
CS2670Y | ACW: 5kV, 20mA |
CS2671AX | ACW: 10kV, 20mA; DCW: 10kV, 10mA |
CS2671BX | ACW: 10kV, 50mA; DCW: 10kV, 20mA |
CS2671TX | ACW: 10kV, 100mA |
CS2672BX | ACW: 5kV, 100mA |
CS2672CX | ACW: 5kV, 100mA DCW: 5kV, 20mA |
CS2672DX | ACW: 5kV, 20mA DCW: 5kV, 10mA |
CS2673X | ACW: 5kV, 200mA |
CS2674AX | ACW: 20kV, 10mA; DCW: 20kV, 10mA |
2.Parameter teknikal
(1)CS2670A/CS2670A-1/CS2670AX
MODEL | CS2670A | CS2670A-1 | CS2670AX | CS2670Y | |||
ACW | Voltan output | (0.00~5.00)kV | |||||
Kuasa output maksimum | 100VA(5.000kV/20mA) | ||||||
Max. semasa | 20mA | ||||||
Julat semasa | 2mA、20mA | ||||||
Output bentuk gelombang | gelombang sinus | ||||||
Bentuk gelombang Herotan | ≤5%(memuatkan atau beban rintangan tulen) | ||||||
Masa ujian | 0.0s ~999s 0=teruskan | ||||||
Meter Volt | Pelbagai | 0.00kV ~ 5.00kV | |||||
Ketepatan | ±(5%+5 perkataan ) | ||||||
Resolusi | 10V | ||||||
Nilai yang dipaparkan | RMS | ||||||
Ammeter | Pelbagai | JA | 0.100mA ~ 20.00mA | ||||
Resolusi | JA | 2mA:1uA, 20mA:10uA | |||||
Ketepatan | ±(5%+5 perkataan ) | ||||||
Pemasa | Pelbagai | 0.0s ~ 999s | |||||
Min. resolusi | 0.1s | ||||||
Ketepatan | ±(1%+50ms) | ||||||
Antara muka PLC | Tidak | Tidak | Ya | Tidak | |||
Antaramuka jauh | Ya | ||||||
(2)CS2671AX/CS2671BX/CS2671TX
MODEL | CS2671AX | CS2671BX | CS2671TX | ||||
AC W | Voltan output | (0.00~10.00)kV | |||||
Max.output Kuasa | 100VA | 500VA | 1000VA | ||||
Max. semasa | 20mA | 50mA | 100mA | ||||
Julat semasa | 2mA、20mA | 2mA、20mA、50mA | 2mA、20mA、100mA | ||||
Output bentuk gelombang | gelombang sinus | ||||||
Bentuk gelombang Herotan | ≤5% | ||||||
Masa ujian | 0.0s ~999s 0.0= teruskan | ||||||
D CW | Voltan output | (0.00~10.00)kV | |||||
Maksimum. output Kuasa | 100VA | 500VA | -------------------- | ||||
Max. semasa | 10mA | 20mA | -------------------- | ||||
Julat semasa | 2mA、10mA | 2mA、20mA | -------------------- | ||||
Faktor Ripple | ≤5% | ||||||
Masa ujian | 0.0s ~999s 0= teruskan | ||||||
Meter Volt | Pelbagai | (0.00~10.00)kV | |||||
Ketepatan | ±(5%+5 perkataan ) | ||||||
Resolusi | 10V | ||||||
Nilai yang dipaparkan | RMS | ||||||
Ammeter | Julat Ukuran | JA | 0.100mA ~ 20.00mA | 0.100mA ~ 50.00mA | 0.100 ~ 100.0mA | ||
DC | 0.100mA ~ 10.00mA | 0.100mA ~ 20.00mA | -------------------- | ||||
Resolusi | JA | 2mA:1uA,20mA:10uA,50mA(100mA):0.1mA | |||||
Ketepatan | ±(5%+5 perkataan ) | ||||||
Pemasa | Pelbagai | 0.0s ~ 999s | |||||
Min. resolusi | 0.1s | ||||||
Ketepatan | ±(1%+50ms) | ||||||
Antara muka PLC | Tidak | Tidak | Ya | ||||
Antaramuka jauh | Ya | ||||||
(3)CS2672BX/CS2672CX/CS2672DX
MODEL | CS2672BX | CS2672CX | CS2672DX | |||
A C W | Output Voltan | (0.00~5.00)kV | ||||
Maxoutput Kuasa | 500VA | 100VA | ||||
Max. semasa | 100mA | 20mA | ||||
Julat semasa | 2mA、20mA、100mA | 2mA、20mA | ||||
Output bentuk gelombang | gelombang sinus | |||||
Bentuk gelombang Herotan | ≤5% | |||||
Masa ujian | 0.0s ~999s 0.0= teruskan | |||||
D C W | Output Voltan | ----------------------------- | (0.00~5.00)kV | (0.00~5.00)kV | ||
Maksimum. output Kuasa | ----------------------------- | 100VA | 50VA | |||
Max. semasa | ----------------------------- | 20mA | 10mA | |||
Julat semasa | ----------------------------- | 2mA、20mA | 2mA、10mA | |||
Faktor Ripple | ----------------------------- | ≤5% | ||||
Masa ujian | ----------------------------- | 0.0s ~999s 0= teruskan | ||||
Meter Volt | Pelbagai | (0.00~50.00)kV | ||||
Ketepatan | ±(5%+5 perkataan ) | |||||
Resolusi | 10V | |||||
Dipaparkan Nilai | RMS | |||||
Ammeter | Julat Ukuran | JA | 0.100mA ~ 100.0mA | 0.100mA ~ 100.0mA | 0.100mA ~ 20.00mA | |
DC | ---------------------------- | 0.100mA ~ 20.00mA | 0.100mA ~ 10.00mA | |||
Resolusi | 2mA:1uA, 20mA:10uA, 50mA:0.1mA | |||||
Ketepatan | ±(5%+5 perkataan ) | |||||
Pemasa | Pelbagai | 0.0s ~ 999s | ||||
Min. resolusi | 0.1s | |||||
Ketepatan | ±(1%+50ms) | |||||
Antara muka PLC | Tidak | Tidak | Ya | |||
Antaramuka jauh | Ya | |||||
(4)CS2673X/CS2674AX
MODEL | CS2673X | CS2674AX | ||||
A C W | Voltan output | (0.00~5.00)kV | (0.00~20.00)kV | |||
Maksimum. output Kuasa | 500VA | 200VA | ||||
Max. semasa | 200mA | 20mA | ||||
Julat semasa | 2mA、20mA、200mA | 2mA、10mA | ||||
Output bentuk gelombang | gelombang sinus | |||||
Bentuk gelombang Herotan | ≤5% | |||||
Masa ujian | 0.0s ~999s 0.0= teruskan | |||||
D C W | Voltan output | -------------------------------- | (0.00~20.00)kV | |||
Maksimum. output Kuasa | -------------------------------- | 200VA | ||||
Max. semasa | -------------------------------- | 10mA | ||||
Julat semasa | -------------------------------- | 2mA、10mA | ||||
Faktor Ripple | ≤5% | |||||
Masa ujian | 0.0s ~999s 0= teruskan | |||||
Meter Volt | Pelbagai | (0.00~5.00)kV | (0.00~20.00)kV | |||
Ketepatan | ±(5%+5 perkataan ) | |||||
Resolusi | 10V | |||||
Nilai yang dipaparkan | RMS | |||||
Ammeter | Julat Ukuran | JA | 0.100mA ~ 200.00mA | 0.100mA ~ 10.00mA | ||
DC | ----------------------------------- | 0.100mA ~ 10.00mA | ||||
Resolusi | 2mA:1uA, 20mA:10uA, 200mA:0.1mA | |||||
Ketepatan | ±(5%+5 perkataan ) | |||||
Pemasa | Pelbagai | 0.0s ~ 999s | ||||
Min. resolusi | 0.1s | |||||
Ketepatan | ±(1%+50ms) | |||||
Antara muka PLC | Tidak | Tidak | Ya | |||
Antaramuka jauh | Ya | |||||