I.Kerangka
This tester is designed and manufactured specially according to the national standard " GB265 – 88 Determination of kinematic viscosity of petroleum products " . It's suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity. This method is suitable to determine kinematic viscosity of liquid petroleum products ( It refers to Newtonian liquids ), and its unit is m2/s. Generally in actual utilization, the unit is mm2/s. The dynamic viscosity is equal with the result which use kinematic viscosity to multiply the density of the liquid. By this method, , it can determine the time that the liquid with the certain volume flows past the calibrated glass capillary viscometer under the gravity in the certain stable temperature and the value that the constant value of capillary in the viscometer multiplies the flowing time, that is , the determined kinematic viscosity of liquid at the temperature. At the temperature, the value that kinematic viscosity multiplies the density of the liquid in the same temperature is the dynamic viscosity at the temperature.
II.Main Functions And Characteristics
(1) LCD screen, with English character , clear to see ,easy operation .
(2) Dengan papan kekunci, anda boleh menyediakan parameter seperti nilai malar viskometer, nilai suhu terkawal, nilai suhu -penala halus, masa ujian dsb. Dan radas mempunyai fungsi ingatan.
(3) Gunakan penderia yang diimport, teknologi digital PID untuk mengawal suhu, mempunyai julat luas untuk mengawal suhu, mempunyai ketepatan tinggi untuk mengawal suhu.
(4) Jam kalendar tiada kuasa mati. Apabila bermula, boleh menunjukkan masa sekarang secara automatik.
(5) Komunikasi rangkaian, boleh memilih fungsi dengan alat kawalan jauh dan glosari.
(6) Apabila menekan pad kekunci, tangan anda berasa sangat baik.
(7) Anda boleh melaraskan masa ujian dari sekali kepada enam kali, supaya anda mudah menjalani ujian.
(8) Anda boleh menyimpan rekod ujian, supaya anda boleh menyemak rekod selepas itu dengan mudah.
III.Spesifikasi Teknikal
(1) Lubang mandian cecair:4
(2) Range to control the temperature:indoor temperature—120 degree
(3) Precision to control the temperature:Room temperature -120 degree Less than or equal to ±0.1 degree
Room temperature -40 degree Less than or equal to ±0.2 degree
(4) Input power source:AC220V±10V 50HZ
(5) Kuasa pemanasan : 1000W
(6) Masa ujian: dari 1 hingga 6 kali, boleh melaraskan.
IV.Syarat Penggunaan
(1) Suhu persekitaran: 0 darjah -40 darjah
(2) Kelembapan relatif:<>